Save money by calling and asking about our Triton 360 Maintenance Plan today!

Triton 360 Furnace Maintenance

Confirm Furnace Efficiency

Safety Inspection of Heat Exchanger

Adjust Fan Speed for the Quietest Operation

Confirm Age & Condition of Equipment

Confirm Age & Condition of Thermostat 

Full Furnace Check

  1. Confirm age and condition of thermostat
  2. Confirm thermostat accuracy. Calibrate if needed/possible
  3. Adjust fan speed for the quietest operation (if possible)
  4. Confirm furnace efficiency
  5. Safety inspection of heat exchanger
  6. Confirm overall condition and age of equipment
  7. Confirm proper filter size and install standard 1″ or 2″
  8. Check integrity & construction of return platform to ensure it meets safety standards
  9. Confirm and inspect interior and exterior upper and lower combustion vents for obstruction
  10. Inspect blower wheel condition
  11. Clean blower motor vents and oil motor (if applicable)
  12. Inspect shaft end play
  13. Test furnace run assist condition
  14. Vacuum and remove debris from furnace platform
  15. Confirm child safety return air door switch is functional
  16. Confirm there is circuit board / ignition surge protection
  17. Clean flame sensor rod (if applicable) and confirm its operation
  18. Clean condensate line and trap (for 90%) efficiency models)
  19. Confirm gas line meets current earthquake and safety standards
  20. Cycle unit and check for flame roll out & distributions in flames shape and color
  21. Perform inlet & manifold gas pressure test
  22. Confirm proper drafting of flue vent
  23. Inspect supply and return grills for obstructions
  24. Inspect ducts for obstructions
  25. Visually inspect accessible ductwork & plenum for breaks, construction, insulation & air leaks
  26. Inspect overall ductwork condition
  27. Inspect attic insulation
  28. Confirm flue vent is up to current code for safety
  29. Confirm the temperature rise within manufactures spec

Triton 360 A/C Maintenance

Inspect Supply & Return Air Grills for Obstructions

Inspect Overall Ductwork Condition

Confirm Outdoor Unit Efficiency

Inspect Attic Insulation

Confirm Age & Condition of Thermostat 

Full A/C Check

  1. Confirm age and condition of thermostat
  2. Confirm thermostat accuracy. Calibrate if needed/possible
  3. Inspect supply & return air grills for obstructions
  4. Inspect ducts for obstructions
  5. Visually inspect accessible ductwork & plenum for proper insulation
  6. Visually inspect accessible ductwork & plenum for breaks, construction, insulation & air leaks
  7. Inspect overall ductwork condition
  8. Inspect attic insulation
  9. Perform static pressure test (every other year)
  10. Clean condensate line with Co2
  11. Confirm outdoor unit efficiency
  12. Confirm overall condition and age of outdoor unit
  13. Visually inspect for refrigerant leaks at outdoor unit
  14. Confirm unit has refrigerant lock-out caps to meet safety and code standards
  15. Oil outdoor fan (if applicable) and check for proper blade balance/vibration
  16. Perform amp draw test on outdoor fan motor
  17. Perform amp draw test on compressor
  18. Confirm line set at outdoor unit for proper insulation
  19. Cursory refrigerant level check using line temperature method
  20. Digital test of refrigerant with precise computer gauge for low operating costs and max performance (performed every other year)
  21. Tighten electrical connections that disconnected and electrical contacts
  22. Confirm fuses and circuit breaks meet manufactures specs
  23. Inspect for excessive pitting, overheating and burnt contacts
  24. Inspect and test outdoor run assist
  25. Inspect and test start assist
  26. Hydro wash outdoor coil – we do not recommend using any chemical cleaners
  27. Inspect corrosion inhibitors
  28. Ensure compressor crankcase heaters are operational
  29. Observe outdoor operating noise level
  30. Confirm outdoor unit is properly leveled

Reach out and become a member now!